Apogee TS-100 Manuel du propriétaire Page 1

Naviguer en ligne ou télécharger Manuel du propriétaire pour Mesure, test et contrôle Apogee TS-100. Apogee TS-100 Owner`s manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 19
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
APOGEEINSTRUMENTS,INC.721WEST1800NORTH,LOGAN,UTAH84321,USA
TEL:(435)7924700FAX:(435)7878268WEB:APOGEEINSTRUMENTS.COM
Copyright © 2013 Apogee Instruments, Inc.
OWNER’S MANUAL
ASPIRATED RADIATION SHIELD
Model TS-100
Vue de la page 0
1 2 3 4 5 6 ... 18 19

Résumé du contenu

Page 1 - ASPIRATED RADIATION SHIELD

APOGEEINSTRUMENTS,INC.721WEST1800NORTH,LOGAN,UTAH84321,USATEL:(435)792‐4700FAX:(435)787‐8268WEB:APOGEEINSTRUMENTS.COMCopyrigh

Page 2 - TABLE OF CONTENTS

10The underside of the hat has eight flat surfaces where one or more included cable tie mounts may affix. Using the cable tie mounts is optional, b

Page 3 - DECLARATION OF CONFORMITY

11OPERATION AND MEASUREMENT Connect the sensor to a measurement device (meter, datalogger, controller) capable of inputting 2.5 V DC, and measurin

Page 4 - INTRODUCTION

12An excitation voltage of 2.5 V DC is recommended to minimize self-heating and current drain, while still maintaining adequate measurement sensiti

Page 5 - SENSOR OPTIONS

13Measurement of PRT resistance is very similar to measurement of thermistor resistance, where a half-bridge measurement is used. An excitation vol

Page 6 - SPECIFICATIONS

14Fan Operation: Under some environmental conditions (e.g., high wind speed, low solar radiation), accurate measurements can be made without runni

Page 7

15MAINTENANCE AND RECALIBRATION At full duty, the fan is designed to last 50,000 hours (5.7 years). Ultimately, this depends on operating conditio

Page 8

16TROUBLESHOOTING AND CUSTOMER SUPPORT Independent Verification of Functionality: Apogee ST-110 temperature sensors yield a resistance proportiona

Page 9 - DEPLOYMENT AND INSTALLATION

17compatible measurement device should have resolution of at least 0.008 mV, in order to produce temperature resolution of less than 0.1 C across t

Page 10

18RETURN AND WARRANTY POLICY RETURN POLICY Apogee Instruments will accept returns within 30 days of purchase as long as the product is in new co

Page 11 - OPERATION AND MEASUREMENT

193. Please write the RMA number on the outside of the shipping container. 4. Return the item with freight pre-paid and fully insured to our facto

Page 12 - 15.273TT

2TABLE OF CONTENTS DECLARATIONOFCONFORMITY……………………………..……………………. 3INTRODUCTION…………………………………………………………………………….. 4SENSOROPTIONS...

Page 13 - 0CR1CR2CT

3DECLARATION OF CONFORMITY CE and ROHS Certificate of Compliance We Apogee Instruments, Inc. 721 W 1800 N Logan, Utah 84321 USA Declare under ou

Page 14

4INTRODUCTION Properties of materials and nearly all biological, chemical, and physical processes are temperature dependent. Temperature is also a

Page 15

5SENSOR OPTIONS TS-100 aspirated radiation shields accommodate multiple air temperature and humidity sensors using sensor port adapters. The follo

Page 16

6SPECIFICATIONS TS-100 Radiation-induced Temperature Increase (RITI): There is no reference standard for the elimination of radiation effects on

Page 17

7digit in the IP rating indicates protection against particle entry. A 5 indicates minimal dust entry with no interference with fan operation. The

Page 18 - RETURN AND WARRANTY POLICY

8ST-300 (Platinum Resistance Thermometer) Measurement Range: -50 to 70 C Measurement Uncertainty: 0.2 C (from -40 to 60 C) Measure

Page 19 - OTHER TERMS

9DEPLOYMENT AND INSTALLATION TS-100 aspirated radiation shields come partially pre-assembled and have few parts, facilitating easy transport, depl

Commentaires sur ces manuels