11
Max. Continuous Amperes
APL-10 / APL-12
Typical Program Conditions
100 / 120V AC
10.5A RMS
7A RMS (
OR LESS)
5.25A RMS
3.5A RMS (
OR LESS)
240V AC
(3) Current Requirements
All power amplifiers require sufficient current for proper operation and the
amplifiers designed into Apogee powered loudspeakers are no exception.
Chart #1 shows the required current for one APL-10 or APL-12 at three
standard international working voltages (120, 240, & 100V AC). Because cur-
rent drain is ultimately a function of the program source, Chart #1 shows
both the theoretical maximum, and what can be expected under typical high-
level program conditions:
We recommend powering no more than one APL-10 or one APL-12 from a
single 20A, 120V AC circuit, and no more than two APL-10 or APL-12 speak-
ers from a single 20A, 240V AC circuit, thereby allowing a margin for line loss
and/or lower than normal voltages.
To determine the total current requirement for a system of powered loud-
speakers, simply add their Maximum Continuous RMS Currents together,
then calculate a safety margin of 25% or greater.
If special length AC cables are required for your powered speakers, they
should be constructed of durable, high-quality portable cordage such as S,
SO, or SJO type.
Chart 2 provides the basic guidelines of The National Electric Code for four
common gauges of copper wire related to permissible load in amperes.
Chart 1
Commentaires sur ces manuels